Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What charge time, hold time, and rep rate are my Type S capacitors rated for?

0
Posted

What charge time, hold time, and rep rate are my Type S capacitors rated for?

0

The nominal conditions used to calculate the life of Type S capacitors are a charge time ≤ 30 seconds and a hold time ≤ 5 seconds. WE recommend that you do not exceed these values. The pulse repetition rate is determined by the capacitor’s maximum allowed rms current which is shown on our Series S, SS, & DE page or on individual specification sheets available from GAEP. To determine the rms current for a capacitor in your application, please use our rms current calculator.