Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What causes the following issues when running SS7 TUP or ISUP protocol?

causes isup Protocol running ss7 tup
0
Posted

What causes the following issues when running SS7 TUP or ISUP protocol?

0

Issue 1: SS7 server (Ss7Monitor.exe) is out of service. Possible causes: 1) Abnormal frame synchronization signal on local or remote E1; 2) Timeslot 16 not set by the remote PBX to transfer signaling messages; 3) Incorrectly configured IP address or parameters concerning signaling in the SS7 server program; 4) The telecoms service provider does not offer SS7 service or service data concerned are not ready; 5) Incorrectly configured local DPC or OPC; 6) Bad or improper board grounding; 7) You might have set the analog board to be master clock when using both digital and analog boards on a single computer. Note that the digital board should always provide the master clock. Issue 2: SS7 signaling links appear to be in a state of circuit reset. Possible causes: 1) Abnormal frame synchronization signal on local or remote E1; 2) Incorrectly configured CIC number of PCM; 3) The telecoms service provider does not offer the relative service or service data concerned are not ready. Issue 3: SS7