What board underlayment products should I put in place before installing resilient floor products?
Underlayments for resilient floors should be structurally sound and designed for resilient flooring underlayment purposes, with a minimum thickness of 1/4″. The panels should be smooth enough so that the texture or graining will not show through the finished flooring. They should also resist dents and punctures from concentrated loads. The panels should not contain any substance that may stain vinyl such as edge patching compounds, marking inks, paints, solvents, adhesives, asphalt, dye, etc. Check with your supplier or panel manufacturer. Install the underlayment in strict accordance with the board manufacturer’s recommendations.