What are your weather conditions or limitations for the application of CERAM-KOTE coatings (low and high)? What happens when CERAM-KOTE is applied on a day with 95% humidity?
Unless in a controlled environment, coating will only be permitted during daylight hours when air and substrate is above 40°F (4.4°C). No coating will be permitted when steel is wet from rain or dew, when surfaces are less than 5°F (3°C) above the dew point and holding or when the relative humidity is greater than 85%. In some CERAM-KOTE systems, moisture will inhibit the catalyst reaction in the coating system and will not cure or perform properly.