Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What are the strengths and limitations to x-ray inspection in “bump” technology?

0
Posted

What are the strengths and limitations to x-ray inspection in “bump” technology?

0

• Strengths: X-ray is excellent for viewing bridging, cold solder, voids, misregistration, plus insufficient and excessive reflow. • Limitations: X-ray is not considered to be effective when inspecting for opens, as typically opens do not appear much different than an insufficient reflow. It is recommended that the use of a BGA scope for optical side viewing be used to compliment the x-ray inspection for opens.