Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What are the separation distance requirements for underground piping?

0
Posted

What are the separation distance requirements for underground piping?

0

• The separation distance for potable water and sewer pipelines located in the public right-of-way is governed by Arizona Administrative Code (AAC) R-18-5-502.C. The separation distance for reclaimed water pipelines located in the public right-of-way is governed by AAC R-18-9-602.F. The Maricopa Association of Government’s “Uniform Standard Details for Public Works Construction” standards 404-1 and 404-2 detail the separation distance and protection requirements for the installation of potable water, reclaimed water and sewer pipelines for MAG participants. The separation distance between potable water and sewer pipelines from other pipelines such as non-potable ground, surface, irrigation, storm, industrial, etc., pipelines located in the public right-of-way is not defined by the regulations or MAG standards. The MCESD recommends that these non-potable pipelines: • Be separated from potable water pipelines as specified by AAC R-18-5-502.C. • Be located no closer than two feet vertical