What are the requirements for certification of SmartCEM-60 PEMS under 40 CFR Part 60, PS-16?
The minimum data required for a SmartCEM PEMS model is from 24 hours to 72 hours of data to build a successful model. The entire range of operations at various loads and including a startup and/or shutodwn is typically required. The initial certification under PS-16 requires a 27-run relative accuracy test audit and statistical analysis of the data. CMC provides a certification guarantee with each SmartCEM product such that the initial testing will meet the requirements of PS-16 and CMC remains involved with the required submittals and reports until notification is received by the appropriate regulatory agencies.