Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What are the Mulveys Under Flooring Heating Guideline?

0
Posted

What are the Mulveys Under Flooring Heating Guideline?

0

Canadia Guidelines for installation over Under-Floor Heating 1. The maximum transfer temperature through the screed may not exceed 28°C. 2. The under-floor heating system should be a Water-based system, not electric matting as they may develop extreme temperatures when covered up. 3. If gluing down use only glue specified for use over under floor heating, If a liquid Damp Proof Membrane is not be used moisture content should be below 3% in the concrete. 4. If floating, TUPLEX underlay must be used, the concrete moisture must be below 3.5% 5. Keeping a stable Relative Air Humidity (RaH) is required to avoid excessive gap forming between the individual boards. Recommend RaC is between 45 and 65 %. 6. The warm water tubing needs to be installed in a fine or medium distance pattern, not exceeding a distance between the tubes of 500 mm. 7. To avoid damage to the sub-floor and the wooden floor make sure that the start-up protocol of the under-floor heating is followed and respected. 8. The u