Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What are the loading rates/head loss figures for the Hydro-Static Screen?

0
Posted

What are the loading rates/head loss figures for the Hydro-Static Screen?

0

A. The Hydro-Static Screen has undergone independent testing at the national CSO testing facility at Wigan Wastewater Treatment Works. Following on from this testing the recommended design loading range for the Hydro-Static Screen is 73 to 143 US gal/min/ft2 (nominal value = 110 US gal/min/ft2 ).