What are the cycling times and data recording requirements?
For opacity – Minimum of one cycle of sampling and analysis for each successive 10-second period and one cycle of data recording for each successive 6-minute period. For all CEM systems except opacity – Minimum of one cycle of operation (sampling, analysis and data recording) for each successive 15-minute period.