Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What are the advantages of measuring suspended solids with a continuous, online analyzer?

0
Posted

What are the advantages of measuring suspended solids with a continuous, online analyzer?

0

1. Balance the solids loading in the mixed liquor as flow changes during the day. 2. Reduce the time required to take manual grab samples. 3. Accurately control wasting, thereby maintaining an optimum sludge age. BACK TO TOP 3. What is the range of suspended solids that can be measured? There are two different sensors that cover a range of 0 to 30,000 mg/l. The model 15L was designed to measure low ranges (0 to 1500 mg/l) typically found in plant and clarifier effluents. The model 15 was designed to measure higher solids concentrations (400 to 30,000 mg/l) typically found in mixed liquor, RAS, and WAS. BACK TO TOP 4. Is there a correlation between suspended solids measured in mg/l and turbidity as measured in NTU’s? No. The mg/l method is a volumetric measure of the actual weight of solids in the sample. The NTU method is a measurement of the clarity of the water. There is no exact correlation between the two methods. BACK TO TOP 5. Is there a method to automatically clean the optics o