What are temperature Limitations of Avian-B and Avian-D?
Avian-B and Avian-D have similar thermal properties in that degradation of the reflectance , especially in the UV and blue regions of the spectrum, begin to degrade if the sprayed coating is maintained above 85° C for more than a few minutes. The degradation is not often visibly apparent, as the coating degrades from the substrate outward. If subjected to temperatures above 120°C for extended periods, a distinct yellow color will appear.