Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What are some other design and construction requirements for exit routes?

0
Posted

What are some other design and construction requirements for exit routes?

0

Exit routes must be permanent parts of the workplace.Exit discharges must lead directly outside or to a street, walkway, refuge area, public way, or open space with access to the outside. These exit discharge areas must be large enough to accommodate the building occupants likely to use the exit route.Exit stairs that continue beyond the level on which the exit discharge is located must be interrupted at that level by doors, partitions, or other effective means that clearly indicate the direction of travel leading to the exit discharge.Exit route doors must be unlocked from the inside. They must be free of devices or alarms that could restrict use of the exit route if the device or alarm fails.Side-hinged exit doors must be used to connect rooms to exit routes. These doors must swing out in the direction of exit travel if the room is to be occupied by more than 50 people or if the room is a high-hazard area.Exit routes must support the maximum permitted occupant load for each floor ser

What is your question?

*Sadly, we had to bring back ads too. Hopefully more targeted.

Experts123