The CobraNet network is synchronized to a single CobraNet device on the network known as the conductor. The conductor generates a timebase from a crystal oscillator or receives it from an external clock source. Based on this timebase, the conductor regularly broadcasts beat packets onto the network. Other devices on the network lock onto the arrival time of this packet and regenerate the clock locally.