Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

The rupture disc keeps breaking early; whats wrong?

breaking Disc early rupture wrong
0
Posted

The rupture disc keeps breaking early; whats wrong?

0

Several factors can limit the usable life span of a rupture disc, or derate the rupture disc, causing it to burst at a lower pressure. Some of these include: • Operating the system above the recommended operating-to-burst-pressure ratio • Handling or installation damage • Damage from corrosive media • “Shock” damage from system pulsations • Improper installation, which may include installing the rupture disc upside down, misaligned/overtorqued/undertorqued discs, failing to install all rupture disc elements, or installing the wrong rupture disc in a particular installation. Some of our rupture disc designs minimize or eliminate some of these problems. If there is a problem with your pressure relief safety system, call our Sales Department at (816) 792-1500. Our Tech Team is skilled in investigating technical problems and finding solutions.

0

Several factors can limit the usable life span of a rupture disc, or derate the rupture disc, causing it to burst at a lower pressure. Some of these include: pressurizing the system above the operating-to-burst-pressure ratio; handling or installation damage; damage from corrosive media; “shock” damage from system pulsations; and improper installation, which may include installing the rupture disc upside down, misaligned, overtorqued, undertorqued, failing to install all rupture disc elements, and installing the wrong rupture disc in a particular installation. Some of our rupture disc designs minimize or eliminate some of these problems. If there is a problem with your overpressure safety system, call us our CDC Tech Team is skilled in investigating problems and finding solutions.

Related Questions

What is your question?

*Sadly, we had to bring back ads too. Hopefully more targeted.

Experts123