The auto update feauture on the IPS 5.0 for NIDS module is not working. How can I resolve this issue?
A. This output shows the complete error message: autoUpgradeServerCheck: uri: ftp://hfcu-inet01@192.168.1.12//ips-update/ packageFileName: result: No installable auto update package found on server status=true This issue occurs because of an improper directory listing style with the FTP server. In order to resolve this, switch to UNIX-style directory listings from the existing MS-DOS style directory listings. In order to modify the directory listing settings, select Start > Program Files > Administrative Tools in order to open the Internet Services Manager. Then go to the Home Directory tab and change the directory listing style from MS-DOS to UNIX.