Table of Contents QUESTION: What is the problem with the Adaptec 1542C and external cables? ANSWER From: Scot Stelter, Adaptec (Product Manager for the AHA-1540)
Several articles lately have cited the importance of SCSI-2-compliant cables when cabling SCSI bus subsystems. Perhaps the most accurate and technically detailed one was published in Computer Technology Review in March ’93 (Volume XIII, No. 3. PP. 6). In short, it explains the double-clocking mechanism that can occur due to cables whose impedance falls below the 90-Ohm SCSI-2 spec. Steep edge speeds on the REQ and ACK lines of the SCSI bus exacerbate the problem, but non-compliant cables are the root cause. Both LAN TIMES in the US (5/24/93, page 115) and CT Magazine in Germany (7/93, page 18) cite this cable problem. In an extensive survey of cables available in the US and Europe, we found that more than half of the cables available have single-ended impedances in the 65 to 80 Ohm range — below the 90 to 132 Ohms specified in the SCSI-2 spec. It seems that some (not all) cable vendors do not understand the specification, describing their cables as SCSI-2 compliant when they are not.