Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Section G2419 Gas Shutoff valves: Can a gas meter shut-off valve be the piping system shut- off, or does the code require both?

0
Posted

Section G2419 Gas Shutoff valves: Can a gas meter shut-off valve be the piping system shut- off, or does the code require both?

0

The “meter valve” addressed in Section G2419.2 is the utility suppliers valve and can not be used as a substitution for the other valves required in Sections G2419.3, G2419.4 and G2419.5. The code does not require a generic “piping system shut-off” on the house side of the meter, except for the “common system” identified in Section G2419.3.

Related Questions

What is your question?

*Sadly, we had to bring back ads too. Hopefully more targeted.

Experts123