respirable fibers released during general maintenance activities that would require the disturbance/removal of the Cirrus® product?
Tests* were conducted to measure respirable fibers generated following the installation, removal/reinstallation of the Cirrus mineral fiber product. In all cases, the results of the monitoring** one hour, and 24 hours, after each activity did not detect the presence of respirable airborne fibers. **Large chamber protocol followed the guidelines of ASTM Standard D5116. The dynamic chamber was operated at one air change per hour and 23×C and 50% relative humidity. **Fiber counts were conducted in accordance with NIOSH Method 7400B.
Related Questions
- Are respirable fibers released during general maintenance activities that would require the disturbance/removal of the Optima® Open Plan product?
- Are respirable fibers released during general maintenance activities that would require the disturbance/removal of the Ultima TM product?
- Are respirable fibers released during general maintenance activities that would require the disturbance/removal of the Cirrus® product?