Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Outlet wiring screwed up?

outlet screwed wiring
0
10 Posted

Outlet wiring screwed up?

0
10

So your $6 outlet tester displays a combination of lights that doesn’t make sense or one or more lights is dim. For example, all three lights are on but K and X (see below) are dim. The three neon bulbs are just between what should be (The first letter is how the light is marked on mine): K Hot to Ground (GROUND OK). O Hot to Neutral (HOT OK?). X Neutral to Ground (HOT/NEUTRAL REVERSE – should not light). I suspect at the very least that your ground is not connected at the service panel. I may run from some/all the outlets but ends somewhere. You are seeing capacitive/inductive pickup between the floating ground and the other wires in the circuit. Your N and H may be reversed as well but this cannot be determined without checking with a load between H/N and a proper ground. I would recommend: 1. Determining if the ground wire for those 3 prong outlets does indeed go anywhere. 2. Determining if the Hot and Neutral polarity is correct by testing between each of the prongs and a confirmed

0

So your $6 outlet tester displays a combination of lights that doesn’t make sense or one or more lights is dim. For example, all three lights are on but K and X (see below) are dim. The three neon bulbs are just between what should be (The first letter is how the light is marked on mine): • K Hot to Ground (GROUND OK). • O Hot to Neutral (HOT OK?). • Neutral to Ground (HOT/NEUTRAL REVERSE – should not light). I suspect at the very least that your ground is not connected at the service panel. I may run from some/all the outlets but ends somewhere. You are seeing capacitive/inductive pickup between the floating ground and the other wires in the circuit. Your N and H may be reversed as well but this cannot be determined without checking with a load between H/N and a proper ground. I would recommend: • Determining if the ground wire for those 3 prong outlets does indeed go anywhere. • Determining if the Hot and Neutral polarity is correct by testing between each of the prongs and a confirm

Related Questions

What is your question?

*Sadly, we had to bring back ads too. Hopefully more targeted.