Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Once an operator has wax filled a casing, does this allow the operator to reprioritize the filled casing within the next integrity re-assessment cycle?

0
Posted

Once an operator has wax filled a casing, does this allow the operator to reprioritize the filled casing within the next integrity re-assessment cycle?

0

Yes. Operators are allowed to reprioritize a casing in an ECDA region based on the new risk assessment conducted in accordance with 49 CFR § 192.917(c). If a wax filled casing is deemed to present less of a threat than an unfilled casing, then it might be deemed a lower priority in the next integrity re-assessment cycle. However, all pipe must be re-assessed every 7 (or fewer) years by an allowable assessment method in accordance with 49 CFR § 192.939(a) and (b).