Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

On a Compact 1000 or a Compact 1250 electric motor, what would cause neither the K1 “Down” contactor, nor the K2 “Up” contactor to operate?

0
Posted

On a Compact 1000 or a Compact 1250 electric motor, what would cause neither the K1 “Down” contactor, nor the K2 “Up” contactor to operate?

0

Either of the following could cause this symptom to happen: · S1, Emergency Stop Switch Element with #27 & #28 wires attached is bad (stuck open). · S5, Thermal Protection switch is bad (stuck open).

Related Questions

What is your question?