Newer gas turbine vendor performance figures how do I use them in GT MASTER?
As in GT PRO, if you know performance figures at just one or a small number of operating conditions, you can re-select the gas turbine to be a User-defined gas turbine and enter the power, heat rate, exhaust flow rate and exhaust temperature for each of the particular cases. If you have performance correction curves, you may want to produce a GT Template representation of the gas turbine. If the performance has minor changes from the existing model, you may be able to tweak the model with the Model Adjustments tab of the [GT Inputs] topic.