Is Transrectal Ultrasonography Really Necessary for Prostate Measurements?
Introduction: The objective of this study was to evaluate the correlation of suprapubic ultrasonography and transrectal ultrasonography in measurements of prostate dimension and volume. Materials and Methods: One hundred consecutive patients with lower urinary tract symptoms were examined by suprapubic and transrectal ultrasonography modalities in a same session. Measurements of the 3 dimensions of the prostate (anteroposterior, transverse, and craniocaudal) and its volume performed by suprapubic ultrasonography were compared with the corresponding measurements by transrectal ultrasonography in order to determine the correlation of the measurements. Prostate volumes were calculated using the ellipsoid formula. Data were further analyzed in subgroups according to prostate volumes smaller or larger than 50 mL, measured by suprapubic ultrasonography. Results: The mean prostate volume of the 100 patients, measured by suprapubic and transrectal ultrasonography were 65.9 ± 35.8 mL and 62.5 ±