Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Is there room for installer error in cutting the slot 5 inches from the roof edge?

0
Posted

Is there room for installer error in cutting the slot 5 inches from the roof edge?

0

Yes, as with most building construction practices, there is some latitude with the precise slot dimensions to be cut. It is recommended that the lower cut for the slot be maintained as close as possible to 5″ from the drip edge flashing and that the slot width be maintained between ¾” to 1″ wide (Note: An edge flashing must be used when installing The Edge Vent). A nice, straight lower cut will assist in properly locating The Edge Vent on the roof with the locating tabs on the underside the product.