Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Is there an easy way to change temperatures over a range using the input grids?

0
Posted

Is there an easy way to change temperatures over a range using the input grids?

0

See steps below. • Using the Pres/Temp/Pipe ID tab of the Input Grid enter the temperature at the first point that you want to change. • Hold down the Shift key, select the last point in the temperature range. This will highlight the range of cells. • Hold down the CTRL key, press Enter, and the temperatures over that range will be updated. Note: Using the CTRL key can do multiple unconnected selection ranges like EXCEL. The new temperature can be entered after the range is selected also. Back to Index Question 101: I am running 12 thermal loadcases (Code B31.1). I noticed in the code combinations that the range from ambient to T1….T12 are considered, however, the total range for all twelve cases are not shown. For example only “T1 to T2”; “T1 to T3” and “T2 to T3” are shown. Answer: Go to Tools/Model Options/Results and enter 2 to 20 in the No. of thermal ranges option. Note: v8.5 has a new Include Max Range comb option which automatically shows only the maximum thermal stress and t