Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Is the signal conditioners default operating mode digital or analog?

0
Posted

Is the signal conditioners default operating mode digital or analog?

0

A. The signal conditioner normally ships in digital mode from the factory, i.e. the Control register is set to 0xFF00. • Q. What is the factory setting of the Configuration register? A. The Configuration register normally contains xxx0000011111111b (or X0FFhex). The xxx (3 MSBs) are the oscillator bits to trim the oscillator frequency as close to 1MHz as possible. • Q. I have mistakenly overwritten the oscillator bits in the Configuration register. Can I recover the factory setting? A. No. If necessary, one should re-trim the oscillator frequency. • Q. The EV kit software does not allow writing to the oscillator bits in the Configuration register. How can I write to these bits? A. The only way to write to these bits with the EVKIT software is to generate a flash file with the oscillator bits set to the desired value. Then, using the EV kit software, perform the “Load Flash from File” operation to write the file into flash. • Q. How critical are the oscillator trim bits in the configura

Related Questions

What is your question?

*Sadly, we had to bring back ads too. Hopefully more targeted.

Experts123