Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Is the pipe supposed to bottom out in the bell for solvent weld joints?

Bell joints pipe solvent weld
0
Posted

Is the pipe supposed to bottom out in the bell for solvent weld joints?

0

Normally no, unless the pipe and bell are at their tolerance extremes. The bell socket is tapered to allow for pipe diameter variances. Typically, the pipe will bottom out at 1/3 to 2/3 of the socket depth. If the pipe does bottom out, the fit should be snug for a good joint. (Refer to ASTM D2855 Section 7.