Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Is the Model VA-2000 applicable for all pool and spa installations?

0
10 Posted

Is the Model VA-2000 applicable for all pool and spa installations?

0
10

Yes, the Model VA-2000 can be installed on any main drain suction line that does not have a suction lift of more than three feet. There are two models available which are suitable for both existing and new construction applications. The Model VA-2000L is designed for suction lift applications, where the circulating or jet pump is located above the water surface level in a pool or spa. The Model VA-2000S is designed for submerged suction applications, where the circulating or jet pump is located below the water surface level in a pool or spa. For pumps operating 24/7 we recommend you install the VA-2000S (even if it is a lift application situation.