Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Is the lead suitable for use inside an insulated glass unit?

glass insulated lead suitable
0
Posted

Is the lead suitable for use inside an insulated glass unit?

0

Yes. European standard EN 1279 makes clear provision for the testing of lead and our profile meet the requirements of EN1279 part 6 in the following ways: Annex C (normative): fogging test Annex G (informative) Volatile test Annex J (informative) Adhesion test Regular testing to the procedures laid out in Annex J are conducted at RegaLead and a certificate of conformity is available upon reqest. Our lead profiles have also been successfully tested using the Canadian Fog Box test by a major US supplier of IG units.