Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Is ProPlex Ethernet suitable for constant coiling and ‘reeling’ applications?

0
Posted

Is ProPlex Ethernet suitable for constant coiling and ‘reeling’ applications?

0

Yes. There are installation guidelines to follow for reeling purpose. 1] The minimum reel core diameter is 10cm. 2] Minimum tension is used during reeling and the unreeling process. 3] Terminate the cable with RJ45 plugs before reeling is initiated. 4] Cable length per reel is less than 90 meters. 5] Recommended to use ruggedized RJ45 connectors such as RJLnxx, RJ Field or Neutrik Ethercon for maximum support. In the core level, under the shields, are 4–twisted pairs and 6 strength members. Two strength members are positioned centrally to perform ‘Tension Relief’ function; the other 4 strength members are twisted around the pairs, each pair being wrapped individually by one of the strength members to perform a ‘Pair Structure Holding’ function. The length of the strength members remains constant and equal to the length of the insulated wires.

Related Questions

What is your question?

*Sadly, we had to bring back ads too. Hopefully more targeted.

Experts123