Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Is it safe to omit the 37 degrees C reading from pretransfusion red blood cell antibody detection testing?

0
Posted

Is it safe to omit the 37 degrees C reading from pretransfusion red blood cell antibody detection testing?

0

The routine pretransfusion red blood cell antibody detection test (PADT), performed at the authors’ institution, consists of a three-phase, saline-antiglobulin technique (immediate spin, 30-minute incubation at 37 degrees C, IgG indirect antihuman globulin test [IAT]), and each phase is examined for hemolysis and agglutination. To determine if it would be safe to omit reading the 37 degrees C phase of the PADT, a 6-year retrospective review of records (February 1986 to February 1992) was undertaken. Of approximately 280,000 sera tested for unexpected red cell alloantibodies, 1480 (.53%) were reactive at only 37 degrees C. Of 1480 sera, 1313 contained alloantibodies of no or questionable significance (eg, anti-Le(a), anti-Leb, and anti-P1), 71 sera contained antibodies of undetermined specificity, and 10 sera were reactive because of rouleaux. Eighty-six serum samples from 53 different patients contained alloantibodies of potential significance (anti-K, anti-E, etc). These 86 sera repre