Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Is a tolerance on hole or hole pattern location specified in the 2005 AISC Code of Standard Practice?

0
Posted

Is a tolerance on hole or hole pattern location specified in the 2005 AISC Code of Standard Practice?

0

No. Neither the ±1/16-in. tolerance, where applicable, on overall length of members framed to other steel parts, nor the 1/16-in. clearance on size of standard holes, should be construed as implying that the tolerance ±1/16 in. also applies either to the maximum tolerance on hole location within a pattern of holes or to the position of intermediate connections.