Is a tolerance on hole or hole pattern location specified in the 2005 AISC Code of Standard Practice?
No. Neither the ±1/16-in. tolerance, where applicable, on overall length of members framed to other steel parts, nor the 1/16-in. clearance on size of standard holes, should be construed as implying that the tolerance ±1/16 in. also applies either to the maximum tolerance on hole location within a pattern of holes or to the position of intermediate connections.