Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

In a divider valve assembly, does it matter what size sections are mounted 1st/2nd/3rd, etc.?

0
Posted

In a divider valve assembly, does it matter what size sections are mounted 1st/2nd/3rd, etc.?

0

Largest section first is preferred. The main reason for this is the long internal flow path from the first piston to its outlet. Small outputs increase the difficulty of bleeding the first section and offer poorer feedback for a blockage signal.