Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

If I use a flame ionization detector (FID) or an infrared (IR) monitor, am I required to determine an annual non-methane organic correction factor?

0
Posted

If I use a flame ionization detector (FID) or an infrared (IR) monitor, am I required to determine an annual non-methane organic correction factor?

0

If the FID or IR monitor measures total hydrocarbons, an annual non-methane organic carbon correction factor must be established, per section 98.344(b)(6)(ii). Some infrared monitors operate in such a manner as to detect only methane; these “methane–specific” analyzer systems do not need to establish or use a correction factor.