Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

If an initial short-term test result is 4 pCi/L (0.02 WL) or higher, what should be done next?

initial PCI short-term Test WL
0
Posted

If an initial short-term test result is 4 pCi/L (0.02 WL) or higher, what should be done next?

0

EPA recommends a follow-up measurement be used to confirm whether radon levels are high enough to warrant mitigation. There are two types of follow-up measurements that may be conducted. The choice depends, in part, on the results of the initial test. An initial measurement result of 10 pCi/L (or 0.05 WL) or greater should be quickly followed by a second short-term test under closed-building conditions. If the average of the initial and second short-term results is equal to or greater than 4 pCi/L (0.02 WL), radon mitigation is recommended. If the average of the short-term test results is less than 4 pCi/L, consider testing again sometime in the future. If the result of the initial measurement is between 4 pCi/L (or 0.02 WL) and 10 pCi/L (or 0.05 WL), the follow-up test may be made with either a short-term or a long-term method. If a long-term follow-up test result is 4 pCi/L (0.02 WL) or higher, EPA recommends remedial action.

0

EPA recommends a follow-up measurement be used to confirm whether radon levels are high enough to warrant mitigation. There are two types of follow-up measurements that may be conducted. The choice depends, in part, on the results of the initial test. An initial measurement result of 10 pCi/L (or 0.05 WL) or greater should be quickly followed by a second short-term test under closed-building conditions. If the average of the initial and second short-term results is equal to or greater than 4 pCi/L (0.02 WL), radon mitigation is recommended. If the average of the short-term test results is less than 4 pCi/L, consider testing again sometime in the future. If the result of the initial measurement is between 4 pCi/L (or 0.02 WL) and 10 pCi/L (or 0.05 WL), the follow-up test may be made with either a short-term or a long-term method. If a long-term follow-up test result is 4 pCi/L (0.02 WL) or higher, EPA recommends remedial action.

0

The EPA recommends a follow-up measurement be used to confirm whether radon levels are high enough to warrant mitigation. There are two types of follow-up measurements that may be conducted. The choice depends, in part, on the results of the initial test. An initial measurement result of 10 pCi/L (or 0.05 WL) or greater should be quickly followed by a second short-term test under closed-building conditions. If the average of the initial and second short-term results is equal to or greater than 4 pCi/L (0.02 WL), radon mitigation is recommended. If the average of the short-term test results is less than 4 pCi/L, consider testing again sometime in the future. If the result of the initial measurement is between 4 pCi/L (or 0.02 WL) and 10 pCi/L (or 0.05 WL), the follow-up test may be made with either a short-term or a long-term method. If a long-term follow-up test result is 4 pCi/L (0.02 WL) or higher, the EPA recommends remedial action. If the long-term follow-up test result is less tha