I receive an error stating “Pure Virtual Function Call” when I try to create an isometric using the Isogen export facility. How do I fix this?
The installation of Isogen assumes most of the files will be installed to Drive C. Additionally, some directory names have been assumed, such as “Common Files.” To correct this problem, find the file sysconfig.mdb, which should be in %system drive%\Program Files\Common Files\Alias\Data. Now … 1a) Open “RegEdit and navigate to HKEY_LOCAL_MACHINE\Software\Alias\Project Manager. b) Once at this key, change the path for FontPath, IsoDirListPath, “SysConfigPath, and TemplatesPath so they all point to the same path location where sysconfig.mdb resides. 2) This problem can also be caused by installing an earlier version of CAESAR II after installing Version 5.00. The earlier version will register its own copy of “pipedll.dll,” which is incompatible with Version 5.00 (in Windows, only one copy of a particular DLL can be registered). The solution is to manually register the “pipedll.dll” in the “Version 5.00” installation directory. The easiest way to accomplish this is to run the “NetUserC2.
Related Questions
- When I try to create an isometric using the Isogen export facility, I receive an error stating "Unexpected error creating isometric, Directory Access is denied." What do I need to do?
- When attempting to create an isometric, using the Isogen export facility, an error stating "Pure Virtual Function Call" is displayed. What is wrong?
- When I try to create an isometric using the Isogen export facility, I receive an error stating "Piping Model Creation Failed." What should I do?