Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

I receive an error stating “Pure Virtual Function Call” when I try to create an isometric using the Isogen export facility. How do I fix this?

0
Posted

I receive an error stating “Pure Virtual Function Call” when I try to create an isometric using the Isogen export facility. How do I fix this?

0

The installation of Isogen assumes most of the files will be installed to Drive C. Additionally, some directory names have been assumed, such as “Common Files.” To correct this problem, find the file sysconfig.mdb, which should be in %system drive%\Program Files\Common Files\Alias\Data. Now … 1a) Open “RegEdit and navigate to HKEY_LOCAL_MACHINE\Software\Alias\Project Manager. b) Once at this key, change the path for FontPath, IsoDirListPath, “SysConfigPath, and TemplatesPath so they all point to the same path location where sysconfig.mdb resides. 2) This problem can also be caused by installing an earlier version of CAESAR II after installing Version 5.00. The earlier version will register its own copy of “pipedll.dll,” which is incompatible with Version 5.00 (in Windows, only one copy of a particular DLL can be registered). The solution is to manually register the “pipedll.dll” in the “Version 5.00” installation directory. The easiest way to accomplish this is to run the “NetUserC2.

Related Questions

What is your question?

*Sadly, we had to bring back ads too. Hopefully more targeted.

Experts123