Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

I have a very lightly loaded plywood roof deck (or wall). Is okay to space ET&F pins at 12 on center everywhere?

0
Posted

I have a very lightly loaded plywood roof deck (or wall). Is okay to space ET&F pins at 12 on center everywhere?

0

No. The maximum spacing of fasteners for plywood attachment should be 6 on center at supported edges and 12 on center at intermediate supports. Be sure to confirm maximum uplift values do not exceed allowable pin pullout values published in ICC ES-4144. Also see the ICC Reports for horizontal diaphragm and shear wall values.