Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

I can’t get the Heim joints to line up with the brackets or I can’t get the bolts in both sides of the Stiffy®, what do I do?

0
Posted

I can’t get the Heim joints to line up with the brackets or I can’t get the bolts in both sides of the Stiffy®, what do I do?

0

The first step is to adjust the preload to the preload on the Stiffy®. Remember the loosest setting is when the distance from the main housing to the top of the adjustment plunger is 15mm; the tightest setting is when that distance is 10mm. From factory the preload is set to 14mm and is on the softer end of the adjustment. Don’t tighten the Locking Jam Nut for the Adjustment Plunger past 35 ft/lbs. Then loosen the Heim Joint Locking Jam Nut and adjust the length of the unit until it matches the bracket. Tighten the Heim Joint Locking Jam Nut and install.