Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How will an operator determine if a pipeline is in an HCA?

determine HCA operator pipeline
0
Posted

How will an operator determine if a pipeline is in an HCA?

0

The potential impact radius must be calculated along the pipeline using the following formula: PIR = 0.69 * (p*d2)0.5 Where: PIR = Potential Impact Radius (in feet) p = maximum allowable operating pressure (in pounds per square inch) d = nominal pipeline diameter (in inches), and 0.69 is a constant applicable to natural gas (constants for other gases must be determined in accordance with Section 3.2 of ASME B31.8S-2001) Pipeline segments for which the circle defined by the potential impact radius includes 20 or more buildings intended for human occupancy or an identified site are considered high consequence areas. Alternatively, Operators may treat all class 3 and 4 locations on their pipelines as high consequence areas. If they elect to use this option, the use of potential impact circles is limited to looking for identified sites in any areas of their pipeline which are not class 3 or class 4 or to considering housing density and identified sites in areas where the potential impact c