How valid is the determination of hematocrit values to detect blood manipulations?
The aim of this paper is a critical reflection of the practice in competitive cycling to use the hematocrit value (Hct) as an indirect control measure for doping with erythropoietin. To demonstrate the individual physiological variation of Hct values, five different studies were performed: 1) Eight subjects were observed (i) during 23 h after a 1 h lasting bout of cycle exercise at 60% of maximum performance and (ii) during 24h under control conditions. 2) Seven subjects were exposed to a 20 min period of -7 head down tilt (HDT), which was followed by 15 min in sitting position. 3) From four subjects blood samples were taken in a sitting position up to 60 min after they had ingested 1 liter isotonic saline solution. 4) Ten subjects performed a vita maxima test on a cycle ergometer, starting at 100W and increasing the workload by 17W every minute. 5) Four elite cyclists participated in a 10 days competition (1,700 km). RESULTS: 1) During the 24h observation period Hct decreased during t