Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How to troubleshoot a hot tub that is not heating Step 1) Is there voltage at the element?

0
Posted

How to troubleshoot a hot tub that is not heating Step 1) Is there voltage at the element?

0

(Is the heat indicator light on?) If there is no voltage, proceed to step 2. If there is voltage, proceed to step 3. Step 2) Check to see if the contactor is open. If it is closed, test the switches between the relay and the element on the primary side. i.e. the high limit switch If the contactor was open, then manually close it and test for voltage at the element. If there is voltage at the element, then replace the contactor. If there is still no voltage at the element, a control switch or circuit on the coil side is open. Test for voltage on the load side of each switch to determine an open circuit. Or, jump from line to coil to determine the side of fault. i.e. check the thermostat, pressure or flow switch, pump switches, blower switch and the top mounted spa side control. Step 3) If you have voltage at the element, test the amperage draw at the element. If there is no amperage draw, replace the heater element. If there is amperage draw, calculate the proper amperage draw using Ohm