Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How to clear the diagnostic code on the controller (control board)?

0
Posted

How to clear the diagnostic code on the controller (control board)?

0

Note: Before clearing the diagnostic code, be sure to find and correct the problem. For the Office Pro units with the old controller (Units manufactured before April 2007 with a green LED): • 1) Unplug the unit and wait for 5 seconds. • 2) Push and hold the HRS and MIN buttons simultaneously. • 3) Then plug the unit in while still holding the buttons. For Classic Plus units with the old controller (Units manufactured before April 2007 with a green LED): • 1) Unplug the unit and wait for 5 seconds. • 2) Push and hold both fan speed buttons simultaneously. • 3) Then plug the unit in while still holding the buttons. For units with the new controller (for all Office Pro and Classic Plus units manufactured from April 2007 to present): Press hold COOL ON/OFF and FAN HI/LO simultaneously for 5 seconds. For units with the new controller: – CL10 & CL18 (Units manufactured from January 2008 to present) – CL40 (Units manufactured from May 2009 to present) – CL60 (Units manufactured from April 200