Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How thick cables need to be for use with the inverter?

cables inverter
0
Posted

How thick cables need to be for use with the inverter?

0

First of all, you should calculate how much current your inverter will be drawing at maximum capacity with the method described above. For example, 100A in the case of a Mass Sine 12/1200. Then count one millimetre per three amps. The standard cable thickness closest to that is 35 mm². This rule applies to cables up to three meters in length. If the inverter is further away from the battery, choose the next size (50 mm² in this case).