Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How should the junctions of non-loadbearing timber studinternal partition walls with timber I-joist or solid timber joist separating floors be constructed?

0
Posted

How should the junctions of non-loadbearing timber studinternal partition walls with timber I-joist or solid timber joist separating floors be constructed?

0

There are alternatives available at both the base and head of partition walls. Either of the two base treatments can be used with either of the two head treatments: 1) Internal partition walls can be constructed either; a) directly off the floating floor treatment (FFT) provided the design meets the FFT manufacturer’s instructions, including additional battens to support the internal walls if necessary, or b) installed off the floor decking, provided the 5mm (min) resilient flanking strip is correctly installed to all perimeters of the floating floor treatment to isolate the floor from all the walls and skirtings For structural reasons, loadbearing internal walls should normally be installed as per option b). 2) At the partition head, internal walls can be installed either; a) up to the ceiling lining fixed via resilient bar noggins, or b) through the ceiling lining and fixed directly to the joists, provided the head plate fully seals the void between the wall linings such that there a

What is your question?

*Sadly, we had to bring back ads too. Hopefully more targeted.

Experts123