Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How much groundwater does an open loop system require?

groundwater loop require system
0
Posted

How much groundwater does an open loop system require?

0

The water requirement of a specific model is usually expressed in gallons per minute (g.p.m.) and is listed in the unit’s specifications. Generally, the average system will use 1.5 g.p.m. per ton of capacity while operating, but the amount of water required depends on the size of the unit and the manufacturer’s specifications. Water Source Heating & Cooling will provide this information. Your well and pump combination should be large enough to supply the water needed by the heat pump in addition to your domestic water requirements. You probably will need to enlarge your pressure tank or modify your plumbing to supply adequate water to the heat pump.