Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How many Tru-Tracs need to be installed on a conveyor?

conveyor installed
0
Posted

How many Tru-Tracs need to be installed on a conveyor?

0

The Tru-TracĀ® needs to be installed at areas where misalignment occurs. The Tru-Trac’s effective tracking distance is approximately 50 metres (160 feet), therefore the Tru-TracĀ® is installed approximately every 50 to 60 meters (160 to 200 feet) per length of conveyor belt, unlike standard idlers/rollers that are installed every 3 to 6 meters (10 to 20 feet).