Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How is the correct splice point identified in the splice command?

Command point Splice
0
Posted

How is the correct splice point identified in the splice command?

0

The command contains a splice_time field. For the execute command the splice_time value must be given in the 90 khz clock ticks. For an Out Point, the splice_time value is set to be the same as the value in the DTS_next_AU field of the Out Point Packet of the PCR_PID. For an In Point, the splice_time value is set to be the same as the value in the DTS_next_AU field of the In Point Packet. The splice_time value may be optionally given as a SMPTE time code in addition to the DTS value. For the schedule command, time code alone may be used.