Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How far can a dryer exhaust vent be run?

dryer exhaust run vent
0
10 Posted

How far can a dryer exhaust vent be run?

0
10

The minimum code requirement is 14 feet with a maximum of 2-90 degree elbows. Every additional elbow subtracts two (2) feet from the maximum distance. The termination shall be in a non-screened eye-brow termination with a back draft damper. Note: If you are installing a specific model of dryer and that dryer allows for a longer run of vent piping then that specific model has to be in place at final and the manufacturer’s installation instructs shall be on site for the inspector to verify.