How does the HLP-10 interface to PSHs?
The HLP-10 has a total of six internal ports into which Interface Modules can be installed. Interface Modules expand functionality of the HLP-10 for increased analog and digital inputs and outputs, modem communication, additional memory and more. The HLP-10 includes one HLIM-9B-001 Interface Module which consumes one of the six available ports. This single HLIM-9 module handles the communication between the HyperLogger and up to 63 PSH’s. With the HLIM-9 installed (as the HLP-10 is delivered) up to five more Interface Modules can be installed for additional capability.